38681Patients who receive mechanical ventilation lose the natural function of their upper airway; therefore, since the upper airway is bypassed the inspired air that a patient receives must be filtered, warmed, and humidified. Humidification should be provided to all patients with an artificial airway to prevent the following:
Dehydration – excessive loss of water
Inspissation of secretions – secretions that are thick and dehydrated
Destruction of airway epithelium – destruction of the thin tissue lining the airways
Re-absorption atelectasis – collapse or incomplete inflation of the lung due to obstruction of the airway
There are two primary types of humidification systems used during invasive mechanical ventilation: active and passive humidifiers. An active humidification system delivers optimal humidity by conditioning inspired gas to body temperature (37°C) and fully saturates the gas with 44mg/L of water vapor. An active humidifier usually consists of a servo-controlled heater which includes a temperature display and alarms. A temperature probe is placed near the patient’s airway and alarms are set on the humidifier to warn of high or low temperatures. The high-temperature alarm should be set at around 37°C to 38°C, so the inspired gas does not exceed 37°C and the low-temperature alarm setting should be set no less than 30°C. Active humidifiers humidify the inspired gas by passing the gas over the surface of a water reservoir or by a moist, heated wick. Two examples of an active humidifier are pass-over and wick humidifiers.
Passive humidifiers do not have an external energy or water source. Passover humidifiers function as an artificial nose. An artificial nose, also referred to as a heat and moisture exchanger (HME), captures the heat and moisture from the expired air and uses it to heat and humidify the inspired gas during inspiration.
Pass-over humidifier

HME

A ventilator may malfunction during use, therefore, alarms are set to warn of possible dangers related to ventilator systems. To avoid alarms being constantly triggered they should not be set so closely, however, they must be adequate to denote changes in the status of the machine and patient. Below are suggestions for setting common ventilator alarms:

Most Commonly Used Ventilator Alarms
High Pressure Alarm
Detects and limits a volume needing too much force to be delivered. Activated by coughing, increase in secretions, decreased compliance or kinks in ETT or circuit
about 10 cmH2O above PIP
Low Pressure Alarm
Detects leaks in the endotracheal tube or ventilator circuit
about 5 – 10 cmH2O below PIP
High Respiratory Rate
Detects an excessively high respiratory rate
about 10 above average rate but not more than 30 breaths/min
Apnea Alarm
Detects cessation of spontaneous breaths
no more than 20 seconds
Low Exhaled VT
Detects leaks in the endotracheal tube or ventilator circuit
about 10% – 15% below set VT
Low PEEP
Initiates when PEEP level decreases. Activated by leaks in the system
about 2 – 5 cmH2O below PEEP level
Prompt
For this assignment, you will provide detailed responses to the following:
Using the AARC Clinical Practice Guidelines, list the indications, contraindications, hazards/complications and limitations for the use of an HME during invasive mechanical ventilation. Be sure to cite your source.
What criteria must be met when using any heated humidification device with patients receiving mechanical ventilation? Why?
When is the use of heated humidifiers preferred over the use of heat and moisture exchangers (HME)?
Submit your answers in at least 500 words on a Word document. You must cite at least three references in APA format to defend and support your position.

Our website has a team of professional writers who can help you write any of your homework. They will write your papers from scratch. We also have a team of editors just to make sure all papers are of HIGH QUALITY & PLAGIARISM FREE. To make an Order you only need to click Ask A Question and we will direct you to our Order Page at WriteDemy. Then fill Our Order Form with all your assignment instructions. Select your deadline and pay for your paper. You will get it few hours before your set deadline.

Fill in all the assignment paper details that are required in the order form with the standard information being the page count, deadline, academic level and type of paper. It is advisable to have this information at hand so that you can quickly fill in the necessary information needed in the form for the essay writer to be immediately assigned to your writing project. Make payment for the custom essay order to enable us to assign a suitable writer to your order. Payments are made through Paypal on a secured billing page. Finally, sit back and relax.

Do you need an answer to this or any other questions?

About Wridemy

We are a professional paper writing website. If you have searched a question and bumped into our website just know you are in the right place to get help in your coursework. We offer HIGH QUALITY & PLAGIARISM FREE Papers.

How It Works

To make an Order you only need to click on “Order Now” and we will direct you to our Order Page. Fill Our Order Form with all your assignment instructions. Select your deadline and pay for your paper. You will get it few hours before your set deadline.

Are there Discounts?

All new clients are eligible for 20% off in their first Order. Our payment method is safe and secure.

Hire a tutor today CLICK HERE to make your first order

Related Tags

Academic APA Writing College Course Discussion Management English Finance General Graduate History Information Justify Literature MLA